01 — Ductwork

Air ducts fabricated with precision, installed with care.

We fabricate galvanized sheet-metal air ducts and fittings, rectangular and round, then install them on site. Every piece is cut to the drawing and matched to the system it serves.

FIG. 01 — Duct assembly

02 — From sheet to duct

From flat sheet to a finished run.

Four controlled stages turn a galvanized sheet into ductwork that fits the building the first time.

SHEET CUT LINE FOLD FIG. 02A — CUT FOLD 90° PROFILE FIG. 02B — FOLD L H SEAM FLANGE FIG. 02C — ASSEMBLE SLAB HANGER ROD OUTLET CEILING FIG. 02D — INSTALL
  1. 01

    Cut

    Galvanized sheet is marked out from the approved drawing and cut to the exact developed size of each panel, with allowances for seams and connections.

  2. 02

    Fold

    Panels are folded into profile with clean, square bends. Seam edges are formed at the same time so the halves lock together without forcing.

  3. 03

    Assemble

    Sections are closed, flanged and sealed along every seam and joint, then checked against the drawing before they leave the workshop.

  4. 04

    Install

    On site, the run is hung level on rods and supports, connected section by section and joined to the air-conditioning equipment and outlets.

03 — Scope

Ductwork for the way each building breathes.

Profiles, finishes and installation are chosen around the air-conditioning system, the space and the route the air has to take.

Rectangular ductwork

The working profile for concealed and ducted systems, sized to fit tight ceiling voids without choking the airflow.

Suited toHomesOfficesShops

Round and spiral ductwork

A smooth, rigid profile that carries air efficiently over longer runs and suits exposed, open-ceiling interiors.

Suited toCommercialProjects

Insulation

Thermal insulation applied to the requirements of each project, to hold supply temperature and keep condensation off the duct.

Suited toSupply runsReturn runs

Site installation

Our own team hangs, connects and seals the run in place, so the people who fabricated it are the ones who fit it.

Suited toNew buildsFit-outs

04 — What we fabricate

Every part of the run, made in-house.

Straight sections and fittings come from the same workshop, so dimensions and connections agree across the whole system.

Straight duct

Elbows

Tees

Reducers and transitions

Outlets and plenum boxes

Hangers and supports

05 — Material

Galvanized steel, chosen for the long run.

A steel core gives the duct its stiffness. A zinc coating on both faces protects it from corrosion inside the ceiling, where no one will look for years.

Material
Galvanized steel sheet
Profiles
Rectangular, round and spiral
Fabrication
Cutting, folding, assembly and sealing
Insulation
To the requirements of each project
Installation
On site, by our own team
FIG. 03 — Galvanized sheet section

06 — Quality

What we check before air moves.

Ductwork is hidden once the ceiling closes. The care has to go in before that.

01Measured on site, not estimated

We take dimensions from the building itself, so each section is made for the space it will occupy.

02Matched to the air-conditioning system

Duct sizes and connections follow the equipment they serve, which keeps airflow balanced and quiet. Explore our HVAC systems

03Sealed seams and joints

Every seam, flange and connection is closed and sealed, so conditioned air reaches the room instead of the ceiling void.

04Level, supported runs

Hangers are spaced and set so the run stays straight and stable for the life of the building.

05Clear handover

We hand over a finished, connected run and walk you through the route, the access points and what was installed where.

07 — How we work

From design drawing to installed run.

One team carries the work from the first measurement to the final connection.

  1. 01

    Measure and design

    We survey the site and prepare the duct layout around the system and the structure.

  2. 02

    Cut

    Sheets are cut to the developed size of every section and fitting.

  3. 03

    Fold and form

    Panels are bent into profile and seam edges are formed.

  4. 04

    Assemble and seal

    Sections are closed, flanged and sealed, then checked against the drawing.

  5. 05

    Install

    The run is hung, connected to the equipment and outlets, and handed over.

A good duct run is measured twice and noticed never.

Contact us

Talk to our HVAC and ductwork team on 0555155235. We will start with a survey.

Call WhatsApp